Design work completed Warnings Message when Design or Check Columns In Etabs !! ⛔ Causes and Effective Solutions IN CASE OF ▶ 1)Axial load on col exceed Euler force ( O/S #5) ◼ this mean Pu > .75 pc ( Euler buckling force ) from code ACI (318-19) δ=(cm/1-pu/.75 pc ) ≥ 1 🔺 SOL increase col Dim because pu affecting ▶2) Delta ns exceed max allowed ◼ this means 1) if col (Non sway) δns > 1.4 and this not allowed 2) if col ( sway ) M2/M1 > 1.4 and this not allowed M2 mean Ult moment with effect P delta (2nd analysis) M1 mean Ult moment without effect P delta (1nd analysis) 🔺 SOL increase width of col not length ▶3) Capacity Ratio Exceed limit ( O/S #35) ◼ This mean capacity ratio for section exceed 1 and (ratio of required for Rft to the used Rft) warning shows in case the column Rft is defined for Check 🔺 SOL increase Dim of col or Rft ratio ▶4) Rft Required Exceeds Max allowed ( O/S #2) ◼ This means that the req Rft ratio exceeds 6% This warning appear in case the column reinforcement is defined for Design not check 🔺SOL increase col Dim
This post was published on 02nd October, 2023 by Bush on his Instagram handle "@etabs_2020 (Etabs)". Bush has total 34.5K followers on Instagram and has a total of 417 post.This post has received 545 Likes which are greater than the average likes that Bush gets. Bush receives an average engagement rate of 1.55% per post on Instagram. This post has received 1 comments which are lower than the average comments that Bush gets. Overall the engagement rate for this post was lower than the average for the profile. #35 #5 #2 has been used frequently in this Post.